ViewVC Help
View File | Revision Log | Show Annotations | View Changeset | Root Listing
root/osprai/osprai/trunk/test.py
(Generate patch)
# Line 1 | Line 1
1   """
2   Christopher Lausted, Institute for Systems Biology
3 < Last modified on 100408 (yymmdd)
4 < Small script to test ba_class, io_module, etc.
3 > Last modified on 100425 (yymmdd)
4 > Small script to test various OSPRAI components.
5   """
6  
7 < ## Import modules.
8 < import vu_module as vu
9 < import io_module as io
10 < ## Reload in case code has changed.
11 < reload (vu)
12 < reload(io)
13 <
14 < #ba1 = io.readbiosensor("example-biosensor.txt")
15 < ba1 = io.readicmtxt("example-icm.txt")
16 < #ba1 = io.readsprit("example-sprit.txt")
17 < #ba1 = io.applykey(ba1, "example-key.tsv")
7 > ## Import libaries
8 > import ba_class
9 > import vu_module
10 > import io_module
11 > import cal_module
12 > import mdl_module
13 > import fit_module
14 > import osprai_one
15 > ## Reload Osprai libraries in case code has changed.
16 > reload(ba_class)
17 > reload (vu_module)
18 > reload(io_module)
19 > reload(cal_module)
20 > reload(mdl_module)
21 > reload(fit_module)
22 > reload(osprai_one)
23 > ## Or just import this next one...
24 > from osprai_one import *
25 >
26 >
27 > print "Test the model module..."
28 > ba0 = BiosensorArray(1,300)  ## Create ba1 with one ROI and 300 datapoints.
29 > roi0 = ba0.roi[0]
30 > roi0.time = arange(300, dtype=float)  ## Samples every 1 second.
31 > roi0.value = zeros(300, dtype=float) + 20  ## Baseline signal is 20 units.
32 > roi0.params = {'t1': {'value':30.0, 'min':30.0, 'max':30.0, 'fixed':True} }
33 > roi0.params['rmax'] =  {'value': 100.0}
34 > roi0.params['conc'] =  {'value': 1e-6}
35 > roi0.params['kon'] =   {'value': 2e4}
36 > roi0.params['t2'] =    {'value': 150.0}
37 > roi0.params['koff'] =  {'value': 1e-3}
38 > roi0.params['t3'] =    {'value': 270.0}
39 > roi0.model = simple1to1
40 > roi0.value =roi0.model(roi0.time, roi0.value, roi0.params)
41 > linegraph(ba0, "Simulation")
42 >
43 > ba1 = copyinterval(ba0, 20, 240)
44 > linegraph(ba1, "Trimmed")
45 > exit()
46 >
47 > print "Testing the fitting..."
48 > ba1 = deepcopy(ba0)
49 > roi0 = ba1.roi[0]
50 > roi0.params['koff'] = {'value':1.0e-2, 'min':1e-8, 'max':1e-1, 'fixed':False}
51 > roi0.params['kon'] =  {'value':1.0e2, 'min':1e1, 'max':1e8, 'fixed':False}
52 > roi0.params['rmax'] =  {'value':50, 'min':1, 'max':90, 'fixed':False}
53 > clma(roi0)
54 > roi0.value =roi0.model(roi0.time, roi0.value, roi0.params)
55 > dualgraph(ba0, ba1, "Fitted Data with an incorrect Rmax parameter")
56 > #exit()
57 >
58 >
59 > print "Loading an SPR data file..."
60 > #ba1 = readbiosensor("example-biosensor.txt")
61 > ba1 = readicmtxt("example-icm.txt")
62 > #ba1 = readsprit("example-sprit.txt")
63 > #ba1 = applykey(ba1, "example-key.tsv")
64   #ba1.set_plot_all()
65   #ba1.set_plot_list(range(6))
66   #ba1.plot()
67  
68 < #io.writesprit(ba1,"testwritesprit.txt")
69 < #io.writeclamp(ba1,"testwriteclamp.txt")
70 < #io.writebiosensor(ba1, "testwritebiosensor.txt")
71 <
72 < vu.linegraph(ba1)
73 < vu.dotgraph(ba1)
74 < vu.dualgraph(ba1, ba1)
68 > #writesprit(ba1,"testwritesprit.txt")
69 > #writeclamp(ba1,"testwriteclamp.txt")
70 > #writebiosensor(ba1, "testwritebiosensor.txt")
71 >
72 > print "Plotting the raw data file..."
73 > linegraph(ba1)
74 > #dotgraph(ba1)
75 > #dualgraph(ba1, ba1)
76 >
77 > print "Plotting the calibrated data..."
78 > ba2 = calibrate(ba1, ba1, 2850, 3120)
79 > linegraph(ba2, "Calibrated SPR Data")
80 >
81 > print "Use ROI #16 as background, subtract, and plot..."
82 > bgset(ba2, 16)
83 > ba2 = bgsubt(ba2)
84 > linegraph(ba2, "Calibrated & Referenced SPR Data")
85 >
86 > print "Test of scatterplot using time points 500, 1000, 1500, 2000"
87 > scatterplot(ba2, 3600, 4200, 3600, 4700, "Scatterplot")
88  
89 < input("Done with test. Press any key")
89 > print "Done with test."

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines